Battery Self Discharge Losses

Units:MW
Mode:Output Only
Multi-band:False
Default Value:
Validation Rule:
Key Property:No
Description:Losses due to self-discharge

Battery Self discharge losses are the losses incurred due to internal self-discharge effects. It is defined as:

Self discharge losses = Self Discharge Rate × time × ½ (Battery Start Energy + Battery End Energy).