Facility Shutdown Penalty

Units:$
Mode:Input Only
Multi-band:False
Default Value:0
Validation Rule:Any Value
Key Property:No
Description:Penalty applied to shutting down a unit

Facility Shutdown Penalty is a penalty applied to shutting down a unit that is additional to the normal Shutdown Cost but is not included in the reported Start & Shutdown Cost. This penalty can be used to affect the optimal unit commitment by either increasing or decreasing a unit's apparent shutdown cost while not affecting the reported costs.