Gas Pipeline Constraints Units Retired Coefficient

Units:-
Mode:Input Only
Multi-band:False
Default Value:0
Validation Rule:Any Value
Key Property:No
Description:Coefficient of number of units retired

Gas Pipeline Constraints Units Retired Coefficient is the left-hand side coefficient in the constraint of the binary (0,1) variable indicating if the Gas Pipeline is retired to date.

With the coefficient represented by a(i,j) the following term is added to the formulation:

... + a(i,j) × ∑ ( t = 1, k ) ( Gas Pipeline Units Retired t ) ... {≤, ≥, =} bj


where:
k
is the current period e.g. year of the simulation.