Units: | $/MW |
Mode: | Input Only |
Multi-band: | False |
Default Value: | -1 |
Validation Rule: | Any Value |
Key Property: | No |
Description: | Price for violating non-anticipativity constraints in scenario-wise decomposition mode |
Generator Build Non-anticipativity applies when the Stochastic Method is set to "scenario-wise decomposition". It is used to identify the first stage build decisions for LT Plan. The property can take any value, but there are two special cases to consider:
Any positive value then acts as a penalty on anticipating the values of the uncertain inputs. It is a useful feature that the non-anticipativity can be relaxed over time as in the following example:
Property | Value | Unit | Date From | Memo |
---|---|---|---|---|
Build Non-anticipativity | -1 | $/MW | This value acts like infinity, so no recourse is available | |
Build Non-anticipativity | 1000 | $/MW | 1/01/2015 | |
Build Non-anticipativity | 100 | $/MW | 1/01/2020 | |
Build Non-anticipativity | 0 | $/MW | 1/01/2025 | Full recourse is now available on these decisions |