Generator Units Shutdown

Units:-
Mode:Output Only
Multi-band:False
Default Value:
Validation Rule:
Key Property:No
Description:Number of units shutdown

Generator Units Shutdown is the number of units that stopped operating in the period, and is defined as:

Units Shutdownt = MAX(0, Units Generating(t-1) - Units Generating(t))

where:
t indexes the time interval; and
Units Generating0 is defined by Initial Units Generating

In summary reporting this is the total number of unit shut downs that occurred in the period.