Generator Constraints Injection Coefficient

Units:GJ (Metric), MMBtu (U.S. Imperial)
Mode:Input Only
Multi-band:False
Default Value:0
Validation Rule:Any Value
Key Property:No
Description:Coefficient of generator heat injection

Generator Constraints Injection Coefficient is the left-hand side coefficient of Generator Heat Injection to heat storage in the constraint.

With the coefficient represented by a(i,j) the following term is added to the formulation:

... + a(i,j) × Generator Heat Injection ... {≤, ≥, =} bj

See also: