Generator Nodes Generation Participation Factor

Units:-
Mode:Input Only
Multi-band:False
Default Value:1
Validation Rule:Between -1 And 1
Key Property:No
Description:Proportion of generator output injected at the node

Generator Nodes Generation Participation Factor is the proportion of generator output injected at the node. Using this property you can split a Generators output across multiple Nodes e.g. for modelling a hydro or other resource where the Generator object aggregates several physical units that inject at different locations.

Example:

Generator Node Property Value Units
AggHydro A220kV Generation Participation Factor 0.9 -
AggHydro A110kV Generation Participation Factor 0.1 -

See also: