NameUnitsMulti-bandDefault ValueValidation RuleKey PropertyDescription
EFC Convergence Threshold%False1≥0FalseConvergence criteria for Reliability evaluation.
EFC Initial EstimateMWFalse0≥0FalseInitial Firm Capacity Estimate for the set of generators associated with the Reliability object.
EFC Risk Metric-False0In (0,1)FalseRisk Metric for EFC evaluation.
Max EFC Iterations-False20≥0FalseMaximum number of ST Schedule iterations for EFC evaluation.
Perform EFC EvaluationYes/NoFalse0In (0,1)FalseFlag indicating if the EFC should be evaluated for the Reliability object.
Simplify Generator PropertiesYes/NoFalse0In (0,1)FalseFlag indicating if Generator properties should be ignored for the model.
Skip StepsYes/NoFalse0In (0,1)FalseIndicates steps that should be skipped.
x-True0FalseValue to pass-through to a solution.
y-True0FalseValue to pass-through to a solution
z-True0FalseValue to pass-through to a solution

Reliability Output Properties

NameSummary NameProperty GroupPhasesMulti-bandDescription
Firm Capacity Contribution - MWFirm Capacity Contribution - MW-LT Plan, MT Schedule, ST ScheduleTrueFirm Capacity Contribution
x xPass-throughLT Plan, MT Schedule, ST ScheduleTrueValue to pass-through to a solution.
y yPass-throughLT Plan, MT Schedule, ST ScheduleTrueValue to pass-through to a solution
z zPass-throughLT Plan, MT Schedule, ST ScheduleTrueValue to pass-through to a solution