Waterway Max Ramp

Units:MW
Mode:Input/Output
Multi-band:False
Default Value:1E+30
Validation Rule:≥0
Key Property:No
Description:Maximum change in flow (MW or cumecs per hour)

Waterway Max Ramp is the maximum change in flow (MW or cumecs per hour). To correctly enforce the constraint in the initial (t=0) period of a chronological simulation (e.g.ST Schedule) you should also define Initial Flow. In the absence of this definition the t=0 ramp constraint is relaxed. This constraint can be made a soft constraint with the Max Ramp Penalty property.