Facility Must-Run Units

Units: -
Mode: Input Only
Multi-band: False
Default Value: 0
Validation Rule: ≥0
Key Property: No
Description: Number of must-run units
Detail:

Facility Must Run Units is the number of units at the facility that must be committed i.e. a lower bound on Units Operating. The optimizer is free to commit more than this number of units up to Available Units.

Note that you can set a fixed commitment, rather than a minimum commitment use the Commit property, however if Must Run Units is set equal to Units the property is converted to Commit automatically.