Fuel Constraints In Use Coefficient
Units: | - |
Mode: | Input Only |
Multi-band: | False |
Default Value: | 0 |
Validation Rule: | Any Value |
Key Property: | No |
Description: | Boolean value (1 if the Fuel is in use, 0 otherwise) |
Detail: |
Fuel Constraints In Use Coefficient is Boolean value (1 if the Fuel is in use, 0 otherwise). You can use this coefficient to place constraints on combinations of fuels used by a Generator when you also add filtering memberships of Generator objects into the Generators collection.
Example
Generator "X" uses Fuels "A", "B", "C", "D":
Collection | Parent Name | Child Name |
---|---|---|
Generator.Fuels | X | A |
Generator.Fuels | X | B |
Generator.Fuels | X | C |
Generator.Fuels | X | D |
Only the combinations "AB" and "CD" are valid. All other combinations must be excluded. To model this we formulate the following constraints:
Class | Name |
---|---|
Constraint | X exclude AC |
Constraint | X exclude AD |
Constraint | X exclude BC |
Constraint | X exclude BD |
Constraint | X select 2 fuels |
Collection | Parent Name | Child Name |
---|---|---|
Generator.Constraints | X exclude AC | X |
Generator.Constraints | X exclude AD | X |
Generator.Constraints | X exclude BC | X |
Generator.Constraints | X exclude BD | X |
Generator.Constraints | X select 2 fuels | X |
Fuel.Constraints | X exclude AC | A |
Fuel.Constraints | X exclude AC | C |
Fuel.Constraints | X exclude AD | A |
Fuel.Constraints | X exclude AD | D |
Fuel.Constraints | X exclude BC | B |
Fuel.Constraints | X exclude BC | C |
Fuel.Constraints | X exclude BD | B |
Fuel.Constraints | X exclude BD | D |
Fuel.Constraints | X select 2 fuels | A |
Fuel.Constraints | X select 2 fuels | B |
Fuel.Constraints | X select 2 fuels | C |
Fuel.Constraints | X select 2 fuels | D |
Membership | Property | Value | Units | Band |
---|---|---|---|---|
Constraint ( X exclude AC ) | Sense | ≤ | - | 1 |
Constraint ( X exclude AC ) | RHS | 1 | - | 1 |
Constraint ( X exclude AD ) | Sense | ≤ | - | 1 |
Constraint ( X exclude AD ) | RHS | 1 | - | 1 |
Constraint ( X exclude BC ) | Sense | ≤ | - | 1 |
Constraint ( X exclude BC ) | RHS | 1 | - | 1 |
Constraint ( X exclude BD ) | Sense | ≤ | - | 1 |
Constraint ( X exclude BD ) | RHS | 1 | - | 1 |
Constraint ( X select 2 fuels ) | RHS | 2 | - | 1 |
Constraint ( X exclude AC ).Fuels ( A ) | In Use Coefficient | 1 | - | 1 |
Constraint ( X exclude AC ).Fuels ( C ) | In Use Coefficient | 1 | - | 1 |
Constraint ( X exclude AD ).Fuels ( A ) | In Use Coefficient | 1 | - | 1 |
Constraint ( X exclude AD ).Fuels ( D ) | In Use Coefficient | 1 | - | 1 |
Constraint ( X exclude BC ).Fuels ( B ) | In Use Coefficient | 1 | - | 1 |
Constraint ( X exclude BC ).Fuels ( C ) | In Use Coefficient | 1 | - | 1 |
Constraint ( X exclude BD ).Fuels ( B ) | In Use Coefficient | 1 | - | 1 |
Constraint ( X exclude BD ).Fuels ( D ) | In Use Coefficient | 1 | - | 1 |
Constraint ( X select 2 fuels ).Fuels ( A ) | In Use Coefficient | 1 | - | 1 |
Constraint ( X select 2 fuels ).Fuels ( B ) | In Use Coefficient | 1 | - | 1 |
Constraint ( X select 2 fuels ).Fuels ( C ) | In Use Coefficient | 1 | - | 1 |
Constraint ( X select 2 fuels ).Fuels ( D ) | In Use Coefficient | 1 | - | 1 |
See also: