Generator Max Heat Rate Tranches

Units: -
Mode: Input Only
Multi-band: False
Default Value: 0
Validation Rule: Between 1 And 100
Key Property: No
Description: Maximum number of tranches in the fuel function piecewise linear approximation.
Detail:

Generator Max Heat Rate Tranches is the maximum number of tranches in the piecewise linear approximation to the fuel function defined by the Heat Rate Model. This property overrides the Production Max Heat Rate Tranches setting for the executing Model.

See also: