Generator Max Load
Units: | MW |
Mode: | Input Only |
Multi-band: | False |
Default Value: | 0 |
Validation Rule: | ≥0 |
Key Property: | No |
Description: | Maximum level of unit load (unit may provide spinning reserve with remainder of spare capacity) |
Detail: |
Generator Max Load sets an upper bound on unit Generation. The Generator is allowed to provide Raise Reserve and/or Regulation Raise Reserve with the remainder of its spare capacity up to the Rating. The property is useful for modelling energy-constrained resources such as hydro that are limited in generation but may still provide reserve.
Example
In the following example the Generator "hydro" is limited in generation by a profile read from a CSV file, but can provide reserve up to its Max Capacity, whereas "solar" is limited through the Rating property and can provide generation and reserve only up to that limit.
Generator | Property | Value | Units | Band | Date From | Date To | Timeslice | Data File |
---|---|---|---|---|---|---|---|---|
hydro | Units | 1 | - | 1 | ||||
hydro | Max Capacity | 100 | MW | 1 | ||||
hydro | Min Load | 0 | MW | 1 | run of river.csv | |||
hydro | Max Load | 0 | MW | 1 | hydro limit.csv | |||
solar | Units | 50 | - | 1 | ||||
solar | Max Capacity | 1 | MW | 1 | ||||
solar | Rating | 0 | MW | 1 | pv.csv |