Generator Max Total Maintenance Percent

Units: %
Mode: Input Only
Multi-band: True
Default Value: 100
Validation Rule: Between 0 And 100
Key Property: No
Description: Maximum percent of total maintenance scheduled within the time frame
Detail:

Generator Max Total Maintenance Percent is maximum percent of total maintenance scheduled within the time frame. Note that two contiguous time frame with the same Max Total Maintenance Percent will be treated as a single time frame in the formulation. This input is used only in PASA.