Generator Min Units Retired in Year

Units: -
Mode: Input Only
Multi-band: False
Default Value: 0
Validation Rule: ≥0
Key Property: No
Description: Minimum number of units automatically retired in any single year of the planning horizon
Detail:

Generator Min Units Retired in Year forces a retirement in a given year in LT Plan. The value should be less than or equal to Max Units Retired.

Table 1: Min Units Retired in Year Example
Property Value Units Date From Date To
Units 1 -

Max Capacity 500 MW

FO&M Charge 50 $/kW/year

Max Units Retired 1 -

Min Units Retired in Year 1 - 1/01/2020 31/12/2020
Retirement Cost 10000 $000


See also: