Generator Must-Run Units
Units: | - |
Mode: | Input Only |
Multi-band: | False |
Default Value: | 0 |
Validation Rule: | ≥0 |
Key Property: | No |
Description: | Number of must-run units |
Detail: |
Generator Must Run Units is the number of units at the facility that must be committed i.e. a lower bound on Units Generating. The optimizer is free to commit more than this number of units up to Available Units.
Note that if you want a fixed commitment, rather than a minimum commitment, then use the Commit property. Please note that if Must Run Units is set equal to Units the property is converted to Commit automatically.