Generator Reserve Share

Units: %
Mode: Input Only
Multi-band: False
Default Value: 0
Validation Rule: Any Value
Key Property: No
Description: Proportion of maximum capacity that must be set aside for reserves
Detail:

Generator Reserve Share defines a percentage of plant capacity this should be set aside for reserve purposes. This property is not related to the detailed reserve cooptimization, but is a simpler mechanism for hardwiring a particular reserve sharing scheme.

Example:

Generator Property Value Units
G1 Reserve Share 15 %
G2 Reserve Share %
G3 Reserve Share 10 %