Generator Constraints Generation Sent Out Coefficient

Units: MW
Mode: Input Only
Multi-band: False
Default Value: 0
Validation Rule: Any Value
Key Property: No
Description: Coefficient of generation measured at the station gate
Detail:

Generator Constraints Generation Sent Out Coefficient is the left-hand side coefficient of Generator Generation in the constraint measured at the station gate i.e. after adjustments for Auxiliary Use.

With the coefficient represented by a(i,j) the following term is added to the formulation:

... + a(i,j) × Generator Aux Incr × Generator Generation ... {≤, ≥, =} bj

See also: