Generator Constraints Generation Sent Out Coefficient
Units: | MW |
Mode: | Input Only |
Multi-band: | False |
Default Value: | 0 |
Validation Rule: | Any Value |
Key Property: | No |
Description: | Coefficient of generation measured at the station gate |
Detail: |
Generator Constraints Generation Sent Out Coefficient is the left-hand side coefficient of Generator Generation in the constraint measured at the station gate i.e. after adjustments for Auxiliary Use.
With the coefficient represented by a(i,j) the following term is added to the formulation:
... + a(i,j) × Generator Aux Incr × Generator Generation ... {≤, ≥, =} bjSee also: