Generator Fuels Emission Scalar
Units: | - |
Mode: | Input Only |
Multi-band: | False |
Default Value: | 1 |
Validation Rule: | Any Value |
Key Property: | No |
Description: | Scalar on emissions from this generator and fuel combination |
Detail: |
This property is used to scale the emissions from a generator that are defined using Emission Generators Production Rate.
Emissions on unit starts are scaled by the property Generator Start Fuels Emission Scalar.
Example
Two types of fuel are used in the generator, Gas and Diesel, producing two types of emissions, NOx and SO2.
The following table reflects the emission production rates by fuel (in lbs per MWh)
Generator | Fuel / Emission | NOx | SO2 |
Gen1 | Gas | 0.6 | 0.1 |
Gen1 | Diesel | 3.0 | 1.0 |
Gen2 | Gas | 0.8 | 0.1 |
If Emission Generators Production Rate is used to determine emissions, then emissions are computed at the same rate for each fuel (which clearly is not the case). By attributing the emissions to the fuel being burned in the generator (using Emission Fuels Production Rate), the proper emissions are computed for SO2, but not for NOx. For emissions such as NOx that are produced both as a function of the fuel used and the generator, the combination of properties Emission.Generators production rate and Generators.Fuels Emissions Scalar is used.
Generator | Fuel | Property | Value |
Gen1 | Gas | Emissions Scalar | 0.6 |
Gen1 | Diesel | Emissions Scalar | 3.0 |
Gen2 | Gas | Emissions Scalar | 0.8 |
Generator | Emission | Property | Value |
Gen1 | NOx | Production Rate | 1.0 |
Gen2 | NOx | Production Rate | 1.0 |
Emission | Fuel | Property | Value |
SO2 | Gas | Production Rate | 0.1 |
SO2 | Diesel | Production Rate | 1.0 |
NOx is computed as the production rate for on generation multiplied by the emissions scalar for Gas of 0.6 (1*.6=.6) on Gen1 and 0.8 (1*.8=.8) on Gen2, and for Diesel of 3 (1*3=3) on Gen1. SO2 is computed based on units of fuel burned using the emission.fuel productions rates as input.
See also: