Charging Station Index

Charging Station Input Properties

NameUnitsMulti-bandDefault ValueValidation RuleKey PropertyDescription
Build Cost$True0FalseCost of building a unit
Charge Efficiency%False100Between 0 And 100FalseEfficiency of charging
Deferment PeriodhTrue0≥0FalseLength of time load is deferred where zero means one interval
Deferrable Load%True0≥0FalseProportion of charging load that can be deferred
Discharge Efficiency%False100Between 0 And 100FalseEfficiency of discharging
Economic LifeyrFalse30≥0FalseEconomic life of the unit (period over which fixed costs are recovered)
Expansion Optimality-False2In (0,2)FalseExpansion planning integerization scheme.
Fixed GenerationMWFalse0≥0FalseFixed generation across all units
Fixed LoadMWFalse0≥0FalseFixed charging load across all units
FO&M Charge$False0FalseAnnual fixed operation and maintenance charge
Max Charge RatekWFalse1E+30FalseMaximum charge rate
Max Discharge RatekWFalse1E+30FalseMaximum discharge rate
Max GenerationMWFalse0≥0FalseMaximum generation across all units
Max LoadMWFalse0≥0FalseMaximum charging load across all units
Max Units Built-False0≥0FalseMaximum number of units automatically constructed in aggregate over the planning horizon
Max Units Built in Year-False1E+30≥0FalseMaximum number of units automatically constructed in any single year of the planning horizon
Max Units Retired-False0≥0FalseMaximum number of units automatically retired in aggregate over the planning horizon
Max Units Retired in Year-False1E+30≥0FalseMaximum number of units automatically retired in any single year of the planning horizon
Min GenerationMWFalse0≥0FalseMinimum generation across all units
Min LoadMWFalse0≥0FalseMinimum charging load across all units
Min Units Built-False0≥0FalseMinimum number of units automatically constructed in aggregate over the planning horizon
Min Units Built in Year-False0≥0FalseMinimum number of units automatically constructed in any single year of the planning horizon
Min Units Retired-False0≥0FalseMinimum number of units automatically retired in aggregate over the planning horizon
Min Units Retired in Year-False0≥0FalseMinimum number of units automatically retired in any single year of the planning horizon
Project Start Date-False36526≥0FalseStart date of generation project, for expansion planning
Retirement Cost$False0FalseCost of retiring a unit
Technical LifeyrFalse1E+30≥0FalseTechnical lifetime of the unit
Units-False0≥0TrueNumber of chargers
UoS Charge$/MWhFalse0FalseUse of system charge
WACC%False10≥0FalseWeighted average cost of capital
x-True0FalseValue to pass-through to solution
y-True0FalseValue to pass-through to solution
z-True0FalseValue to pass-through to solution

Charging Station Output Properties

NameSummary NameProperty GroupPhasesMulti-bandDescription
Annualized Build Cost - $000Annualized Build Cost - $000ExpansionLT PlanFalseAnnualized cost of units built
Build Cost - $000Build Cost - $000ExpansionLT PlanFalseCost of building a unit
Capacity Built - kWCapacity Built - kWExpansionLT PlanFalseCapacity built
Capacity Retired - kWCapacity Retired - kWExpansionLT PlanFalseCapacity retired
Charge Cost - $Charge Cost - $000ProductionLT Plan, MT Schedule, ST ScheduleFalseCost of charging
Charge Price - c/kWhCharge Price - c/kWhProductionLT Plan, MT Schedule, ST ScheduleFalsePrice paid charging
Charging - kWCharging - MWhProductionLT Plan, MT Schedule, ST ScheduleFalseLoad from charging
Deferred Load - kWDeferred Load - MWhProductionLT Plan, MT Schedule, ST ScheduleFalseDeferred charging load
Discharge Price - c/kWhDischarge Price - c/kWhProductionLT Plan, MT Schedule, ST ScheduleFalsePrice received discharging
Discharge Revenue - $Discharge Revenue - $000ProductionLT Plan, MT Schedule, ST ScheduleFalseRevenue from discharging
Discharging - kWDischarging - MWhProductionLT Plan, MT Schedule, ST ScheduleFalseGeneration from discharging
FO&M Cost - $FO&M Cost - $000ProductionLT Plan, MT Schedule, ST ScheduleFalseFixed operation and maintenance cost
Hours Deferred - hHours Deferred - hProductionLT Plan, MT Schedule, ST ScheduleFalseAverage hours load is deferred in the period
Inertia - MW·sInertia - GW·sProductionLT Plan, MT Schedule, ST ScheduleFalseProvision of inertia
Installed Capacity - kWInstalled Capacity - kWProductionLT Plan, PASA, MT Schedule, ST ScheduleFalseTotal charging capacity of the station
Losses - kWLosses - MWhProductionLT Plan, MT Schedule, ST ScheduleFalseTotal charge and discharge losses
Lower Reserve - kWLower Reserve - MWhProductionLT Plan, MT Schedule, ST ScheduleFalseProvision of lower (spin down) reserve
Net Charge Cost - $Net Charge Cost - $000ProductionLT Plan, MT Schedule, ST ScheduleFalseNet of cost of charging and revenue from discharging
Raise Reserve - kWRaise Reserve - MWhProductionLT Plan, MT Schedule, ST ScheduleFalseProvision of raise (spin up) reserve
Regulation Lower Reserve - kWRegulation Lower Reserve - MWhProductionLT Plan, MT Schedule, ST ScheduleFalseProvision of regulation lower reserve
Regulation Raise Reserve - kWRegulation Raise Reserve - MWhProductionLT Plan, MT Schedule, ST ScheduleFalseProvision of regulation raise reserve
Replacement Reserve - kWReplacement Reserve - MWhProductionLT Plan, MT Schedule, ST ScheduleFalseProvision of replacement reserve
Reserves Revenue - $Reserves Revenue - $000ProductionLT Plan, MT Schedule, ST ScheduleFalseRevenue from provision of reserves
Retirement Cost - $000Retirement Cost - $000ExpansionLT PlanFalseCost of retiring a unit
Total Cost - $000Total Cost - $000ExpansionLT PlanFalseTotal of fixed and variable costs
Units UnitsProductionLT Plan, MT Schedule, ST ScheduleFalseNumber of chargers
Units Built Units BuiltExpansionLT PlanFalseNumber of units built
Units Retired Units RetiredExpansionLT PlanFalseNumber of units retired
UoS Cost - $UoS Cost - $000ProductionLT Plan, MT Schedule, ST ScheduleFalseTotal use of system cost
x xPass-throughLT Plan, MT Schedule, ST ScheduleTrueValue to pass-through to solution
y yPass-throughLT Plan, MT Schedule, ST ScheduleTrueValue to pass-through to solution
z zPass-throughLT Plan, MT Schedule, ST ScheduleTrueValue to pass-through to solution