Water Pipeline Index
Water Pipeline Input Properties
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Build Cost | $000 | True | 0 | False | Cost of building the Water pipeline | |
Consumption Allocation | - | False | 0.5 | Between 0 And 1 | False | Proportion of the electricity consumption allocated to the receiving water node |
Diameter | m (Metric), ft (U.S. Imperial) | False | 0.762 | ≥0 | False | Water Pipeline diameter |
Economic Life | yr | False | 30 | ≥0 | False | Economic life of the Water pipeline (period over which fixed costs are recovered). |
Energy Consumed Amount | MW | True | 0 | ≥0 | False | Energy consumption defining the pipeline energy consumption curve. |
Energy Consumed Flow Level | m³/day (Metric), gal./day (U.S. Imperial) | True | 0 | ≥0 | False | Flow level defining the water pipeline energy consumption curve. |
Expansion Max Capacity | m³/day (Metric), gal./day (U.S. Imperial) | False | 1E+30 | ≥0 | False | Expansion max daily total water release for the pipeline |
Expansion Optimality | - | False | 2 | In (0,2) | False | Expansion planning integerization scheme. |
Expansion Pipeline | - | False | 0 | In (0,1) | False | Indicates if the water pipeline is eligible for expansion planning |
Flow Rate Point | m³/day (Metric), gal./day (U.S. Imperial) | True | 0 | ≥0 | False | Flow rate point for the system curve |
FO&M Charge | $000 | False | 0 | False | Annual fixed operation and maintenance charge | |
Forced Outage Rate | % | True | 0 | Between 0 And 100 | False | Expected proportion of time the facility is unavailable due to forced outage |
Head Point | m (Metric), ft (U.S. Imperial) | True | 0 | ≥0 | False | Head point for the system curve |
Is Available | Yes/No | False | 1 | In (0,1) | False | Indicates if Water Pipeline is available for flow. |
Is Bidirectional | - | False | 0 | In (0,1) | False | Indicates if the pipeline allows flow in both directions |
Lead Time | yr | False | 0 | ≥0 | False | Number of years after which the expansion project can begin |
Length | m (Metric), ft (U.S. Imperial) | False | 0 | ≥0 | False | Length of the Water Pipeline |
Maintenance Frequency | - | True | 0 | ≥0 | False | Frequency of maintenance outages in an annual time frame |
Maintenance Rate | % | True | 0 | Between 0 And 100 | False | Expected proportion of time the facility is unavailable due to maintenance |
Max Capacity | m³/day (Metric), gal./day (U.S. Imperial) | False | 1E+30 | ≥0 | False | Maximum flow rate on the water pipeline |
Max Time To Repair | h | True | 0 | ≥0 | False | Maximum time to repair |
Mean Time to Repair | h | True | 24 | ≥0 | False | Mean time to repair |
Min Time To Repair | h | True | 0 | ≥0 | False | Minimum time to repair |
Outage Rating | m³/day (Metric), gal./day (U.S. Imperial) | True | 0 | False | Water pipeline Max Capacity during the outage | |
Project Start Date | - | False | 36526 | ≥0 | False | Start date of Water pipeline project, for expansion planning. |
Pump Efficiency | % | False | 70 | Between 0 And 100 | False | Efficiency of Water Pipeline pump |
Random Number Seed | - | False | 0 | Between 0 And 2147483647 | False | Random number seed assigned to the pipeline for the generation of outages |
Repair Time Distribution | - | True | -1 | In (-1,0,1,2,3,4,5,6,7) | False | Distribution used to generate repair times (Auto,Constant,Uniform,Triangular,Exponential,Weibull,Lognormal,SEV,LEV) |
Repair Time Scale | - | True | 0 | False | Repair time function scale parameter (for exponential,Weibull,lognormal,SEV,LEV) | |
Repair Time Shape | - | True | 0 | False | Repair time function shape parameter (for Weibull,lognormal) | |
Retirement Cost | $000 | False | 0 | False | Cost of retiring the Water pipeline | |
Retirement Pipeline | - | False | 0 | In (0,1) | False | Indicates if the water pipeline is eligible for retirement planning |
Roughness | - | False | 150 | ≥0 | False | Water Pipeline roughness constant |
System Curve Coefficient A | - | False | 0 | False | System curve coefficient A for the quadratic term | |
System Curve Coefficient B | - | False | 0 | False | System curve coefficient B for the linear term | |
System Curve Coefficient C | - | False | 0 | False | System curve coefficient C for the constant term | |
Technical Life | yr | False | 1E+30 | ≥0 | False | Technical lifetime of the Water pipeline |
VO&M Charge | $/m³ (Metric), $/gal. (U.S. Imperial) | True | 0 | False | Variable operations and maintenance costs of the Water Pipeline | |
WACC | % | False | 10 | ≥0 | False | Weighted average cost of capital |
x | - | True | 0 | False | Value to pass-through to solution | |
y | - | True | 0 | False | Value to pass-through to solution | |
z | - | True | 0 | False | Value to pass-through to solution |
Water Pipeline Maintenances Input Properties
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Outage Rating | m³/day (Metric), gal./day (U.S. Imperial) | False | 0 | False | Max Rating during the outage |
Water Pipeline Constraints Input Properties
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Flow Back Coefficient | m³ (Metric), gal. (U.S. Imperial) | False | 0 | False | Coefficient of Water Pipeline flow at the sending node | |
Flow Coefficient | m³ (Metric), gal. (U.S. Imperial) | False | 0 | False | Coefficient of Water Pipeline flow | |
Flow Forward Coefficient | m³ (Metric), gal. (U.S. Imperial) | False | 0 | False | Coefficient of Water Pipeline flow at the receiving node | |
Units Built Coefficient | - | False | 0 | False | Coefficient of number of units built | |
Units Built in Year Coefficient | - | False | 0 | False | Coefficient of number of units built in the year | |
Units Retired Coefficient | - | False | 0 | False | Coefficient of number of units retired | |
Units Retired in Year Coefficient | - | False | 0 | False | Coefficient of number of units retired in the year |
Water Pipeline Objectives Input Properties
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Flow Back Coefficient | m³ (Metric), gal. (U.S. Imperial) | False | 0 | False | Coefficient of Water Pipeline flow at the sending node | |
Flow Coefficient | m³ (Metric), gal. (U.S. Imperial) | False | 0 | False | Coefficient of Water Pipeline flow | |
Flow Forward Coefficient | m³ (Metric), gal. (U.S. Imperial) | False | 0 | False | Coefficient of Water Pipeline flow at the receiving node | |
Units Built Coefficient | - | False | 0 | False | Coefficient of number of units built | |
Units Built in Year Coefficient | - | False | 0 | False | Coefficient of number of units built in the year | |
Units Retired Coefficient | - | False | 0 | False | Coefficient of number of units retired | |
Units Retired in Year Coefficient | - | False | 0 | False | Coefficient of number of units retired in the year |
Water Pipeline Output Properties
Name | Summary Name | Property Group | Phases | Multi-band | Description |
---|---|---|---|---|---|
Build Cost - $000 | Build Cost - $000 | Expansion | LT Plan | False | Cost of building the Water pipeline |
Energy Consumption - MW | Energy Consumption - GWh | Production | LT Plan, MT Schedule, ST Schedule | False | Total energy consumed for pipeline utilization |
Fixed Costs - $ | Fixed Costs - $000 | Production | LT Plan, MT Schedule, ST Schedule | False | Total fixed costs including amortized build costs |
Flow - m³/day (Metric), gal./day (U.S. Imperial) | Flow - m³ (Metric), gal. (U.S. Imperial) | Production | LT Plan, MT Schedule, ST Schedule | False | Quantity of water extracted from the pipeline |
Flow Capacity Outage - m³/day (Metric), gal./day (U.S. Imperial) | Reliability | LT Plan, MT Schedule, ST Schedule | False | Flow capacity on outage due to maintenance or forced outage | |
FO&M Cost - $ | FO&M Cost - $000 | Production | LT Plan, MT Schedule, ST Schedule | False | Fixed operation and maintenance cost |
Forced Outage - m³/day (Metric), gal./day (U.S. Imperial) | Forced Outage - m³ (Metric), gal. (U.S. Imperial) | Reliability | LT Plan, MT Schedule, ST Schedule | False | Capacity forced out |
Forced Outage Hours - h | Forced Outage Hours - h | Reliability | LT Plan, MT Schedule, ST Schedule | False | Number of hours the pipeline is on forced outage |
Hours Congested - h | Hours Congested - h | Production | LT Plan, MT Schedule, ST Schedule | False | Number of hours the pipeline is congested in the reference direction |
Hours Congested Back - h | Hours Congested Back - h | Production | LT Plan, MT Schedule, ST Schedule | False | Number of hours the pipeline is congested in the counter-reference direction |
Maintenance - m³/day (Metric), gal./day (U.S. Imperial) | Maintenance - m³ (Metric), gal. (U.S. Imperial) | Reliability | LT Plan, PASA, MT Schedule, ST Schedule | False | Capacity out on maintenance |
Maintenance Hours - h | Maintenance Hours - h | Reliability | LT Plan, MT Schedule, ST Schedule | False | Number of hours the pipeline is on maintenance |
Max Capacity Built - m³/day (Metric), gal./day (U.S. Imperial) | Max Capacity Built - m³/day (Metric), gal./day (U.S. Imperial) | Expansion | LT Plan | False | Amount of increase in Water Pipeline Max Capacity |
Max Capacity Retired - m³/day (Metric), gal./day (U.S. Imperial) | Max Capacity Retired - m³/day (Metric), gal./day (U.S. Imperial) | Expansion | LT Plan | False | Amount of reduction in Water Pipeline Max Capacity |
Production Cost - $ | Production Cost - $000 | Production | LT Plan, MT Schedule, ST Schedule | False | Cost of extracting water from the pipeline |
Retirement Cost - $000 | Retirement Cost - $000 | Expansion | LT Plan | False | Cost of retiring the Water pipeline |
Service Factor - % | Service Factor - % | Reliability | LT Plan, MT Schedule, ST Schedule | False | Proportion of pipeline capacity available |
Units Out | Reliability | LT Plan, MT Schedule, ST Schedule | False | Number of units out of service | |
x | x | Pass-through | LT Plan, PASA, MT Schedule, ST Schedule | True | Value to pass-through to solution |
y | y | Pass-through | LT Plan, PASA, MT Schedule, ST Schedule | True | Value to pass-through to solution |
z | z | Pass-through | LT Plan, MT Schedule, ST Schedule | True | Value to pass-through to solution |