Water Pump Index

Water Pump Input Properties

NameUnitsMulti-bandDefault ValueValidation RuleKey PropertyDescription
Commit-False-1≥-1FalseNumber of units that should be committed
Efficiency%False0≥0FalseWater Pump efficiency
Flow Rate Pointm³/day (Metric), gal./day (U.S. Imperial)True0≥0FalseFlow rate point for the pump curve
Head Pointm (Metric), ft (U.S. Imperial)True0≥0FalseHead point for the pump curve
Initial Hours DownhFalse1E+30≥0FalseHours the pump has been down for at time zero
Initial Hours UphFalse0≥0FalseHours the pump has been up for at time zero
Max Down TimehFalse0≥0FalseMaximum number of hours a pump can be off after being shut down
Max Flow Ratem³/day (Metric), gal./day (U.S. Imperial)False0≥0FalseMax Flow Rate
Max Headm (Metric), ft (U.S. Imperial)False0≥0FalseMax pump head
Max Starts-False1E+30≥0FalseMaximum number of starts allowed
Max Starts Day-False1E+30≥0FalseMaximum number of starts allowed in a day
Max Starts Hour-False1E+30≥0FalseMaximum number of starts allowed in a hour
Max Starts Month-False1E+30≥0FalseMaximum number of starts allowed in a month
Max Starts Penalty$False-1FalsePenalty applied to violations of [Max Starts] constraints
Max Starts Week-False1E+30≥0FalseMaximum number of starts allowed in a week
Max Starts Year-False1E+30≥0FalseMaximum number of starts allowed in a year
Max Up TimehFalse0≥0FalseMaximum number of hours a pump can be run after being started
Min Down TimehFalse0≥0FalseMinimum number of hours a pump must be off after being shut down
Min Up TimehFalse0≥0FalseMinimum number of hours a pump must be run after being started
Must-Run Units-False0≥0FalseNumber of must-run units
Pump Curve Coefficient A-False0FalsePump Curve Coefficient A for the quadratic term
Pump Curve Coefficient B-False0FalsePump Curve Coefficient B for the linear term
Pump Curve Coefficient C-False0FalsePump Curve Coefficient C for the constant term
Shutdown Cost$False0≥0FalseCost of shutting down a unit
Start Cost$False0≥0FalseCost of starting a unit
Units-False1≥0TrueNumber of installed units
Units Out-False0≥0FalseNumber of units out of service

Water Pump Constraints Input Properties

NameUnitsMulti-bandDefault ValueValidation RuleKey PropertyDescription
Units Started Coefficient-False0FalseCoefficient on the number of unit start

Water Pump Output Properties

NameSummary NameProperty GroupPhasesMulti-bandDescription
Flow Rate - m³/day (Metric), gal./day (U.S. Imperial)Flow Rate - m³/day (Metric), gal./day (U.S. Imperial)ProductionLT Plan, MT Schedule, ST ScheduleFalsePump flow rate
Head - m (Metric), ft (U.S. Imperial)Head - m (Metric), ft (U.S. Imperial)ProductionLT Plan, MT Schedule, ST ScheduleFalsePump head
Operating Cost - $Operating Cost - $000ProductionLT Plan, MT Schedule, ST ScheduleFalseElectric cost of operating the pump
Power - MWPower - MWProductionLT Plan, MT Schedule, ST ScheduleFalsePower consumed by the pump
Start & Shutdown Cost - $Start & Shutdown Cost - $000ProductionLT Plan, MT Schedule, ST ScheduleFalseCost of pump starts and shutdowns
Units Operating Units OperatingProductionLT Plan, MT Schedule, ST ScheduleFalsethe number of units on the pump operating in a given period