Water Pump Station Index
Water Pump Station Input Properties
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Configuration | - | False | 0 | In (0,1) | False | Water Pump configuration (series or parallel) |
Max Flow Rate | m³/day (Metric), gal./day (U.S. Imperial) | False | 1E+30 | ≥0 | False | Maximum flow rate of pump station |
Max Head | m (Metric), ft (U.S. Imperial) | False | 1E+30 | ≥0 | False | Maximum head of pump station |
Max Power | MW | False | 1E+30 | ≥0 | False | Maximum power of pump station |
Water Pump Station Constraints Input Properties
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Flow Rate Coefficient | - | False | 0 | False | Coefficient of Water Pump Station flow rate | |
Head Coefficient | - | False | 0 | False | Coefficient of Water Pump Station head | |
Power Coefficient | - | False | 0 | False | Coefficient of Water Pump Station power |
Water Pump Station Objectives Input Properties
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Flow Rate Coefficient | - | False | 0 | False | Coefficient of Water Pump Station flow rate | |
Head Coefficient | - | False | 0 | False | Coefficient of Water Pump Station head | |
Power Coefficient | - | False | 0 | False | Coefficient of Water Pump Station power |
Water Pump Station Output Properties
Name | Summary Name | Property Group | Phases | Multi-band | Description |
---|---|---|---|---|---|
Energy - MWh | Energy - MWh | Production | LT Plan, MT Schedule, ST Schedule | False | Energy consumption over a given period |
Flow Rate - m³/day (Metric), gal./day (U.S. Imperial) | Flow Rate - m³/day (Metric), gal./day (U.S. Imperial) | Production | LT Plan, MT Schedule, ST Schedule | False | Pump station flow rate |
Head - m (Metric), ft (U.S. Imperial) | Head - m (Metric), ft (U.S. Imperial) | Production | LT Plan, MT Schedule, ST Schedule | False | Pump station head |
Power - MW | Power - MW | Production | LT Plan, MT Schedule, ST Schedule | False | Power consumed by the pump station to achieve the given head and flow rate |
Volume Pumped - m³ (Metric), gal. (U.S. Imperial) | Volume Pumped - m³ (Metric), gal. (U.S. Imperial) | Production | LT Plan, MT Schedule, ST Schedule | False | Volume pumped over a given period |