Water Pump Station Index

Water Pump Station Input Properties

NameUnitsMulti-bandDefault ValueValidation RuleKey PropertyDescription
Configuration-False0In (0,1)FalseWater Pump configuration (series or parallel)
Max Flow Ratem³/day (Metric), gal./day (U.S. Imperial)False1E+30≥0FalseMaximum flow rate of pump station
Max Headm (Metric), ft (U.S. Imperial)False1E+30≥0FalseMaximum head of pump station
Max PowerMWFalse1E+30≥0FalseMaximum power of pump station

Water Pump Station Constraints Input Properties

NameUnitsMulti-bandDefault ValueValidation RuleKey PropertyDescription
Flow Rate Coefficient-False0FalseCoefficient of Water Pump Station flow rate
Head Coefficient-False0FalseCoefficient of Water Pump Station head
Power Coefficient-False0FalseCoefficient of Water Pump Station power

Water Pump Station Objectives Input Properties

NameUnitsMulti-bandDefault ValueValidation RuleKey PropertyDescription
Flow Rate Coefficient-False0FalseCoefficient of Water Pump Station flow rate
Head Coefficient-False0FalseCoefficient of Water Pump Station head
Power Coefficient-False0FalseCoefficient of Water Pump Station power

Water Pump Station Output Properties

NameSummary NameProperty GroupPhasesMulti-bandDescription
Energy - MWhEnergy - MWhProductionLT Plan, MT Schedule, ST ScheduleFalseEnergy consumption over a given period
Flow Rate - m³/day (Metric), gal./day (U.S. Imperial)Flow Rate - m³/day (Metric), gal./day (U.S. Imperial)ProductionLT Plan, MT Schedule, ST ScheduleFalsePump station flow rate
Head - m (Metric), ft (U.S. Imperial)Head - m (Metric), ft (U.S. Imperial)ProductionLT Plan, MT Schedule, ST ScheduleFalsePump station head
Power - MWPower - MWProductionLT Plan, MT Schedule, ST ScheduleFalsePower consumed by the pump station to achieve the given head and flow rate
Volume Pumped - m³ (Metric), gal. (U.S. Imperial)Volume Pumped - m³ (Metric), gal. (U.S. Imperial)ProductionLT Plan, MT Schedule, ST ScheduleFalseVolume pumped over a given period