Line Flow Non-anticipativity Time
Units: | h |
Mode: | Input Only |
Multi-band: | False |
Default Value: | 0 |
Validation Rule: | ≥0 |
Key Property: | No |
Description: | Window of time over which to enforce non-anticipativity constraints in scenario-wise decomposition |
Detail: |
Line Flow Non-anticipativity Time sets the time frame over which flows on the Line are non-anticipative decisions in a stochastic optimization. This property must be used in conjunction with Flow Non-anticipativity.
See also: