Model Objective Absolute Tolerance
Units: | - |
Default Value: | 0 |
Validation Rule: | ≥0 |
Description: | Allowable degradation for the objective when doing hierarchical multi-objective optimization for MIP models |
Detail: |
During Hierarchical Multi-objective optimization, the highest priority objective is optimized (say minimized) first (say to a value X). While optimizing the second objective we add a constraint obj1 <= X to make sure the first objective does not deteriorate relative tolerance if the absolute value by which we allow this degradation.