Power2X Constraints Regulation Raise Reserve Provision Coefficient
Units: | MW |
Mode: | Input Only |
Multi-band: | False |
Default Value: | 0 |
Validation Rule: | Any Value |
Key Property: | No |
Description: | Coefficient of regulation raise reserve provision |
Detail: |
Power2X Constraints Regulation Regulation Raise Reserve Provision Coefficient defines a left-hand side coefficient on the facility's provision of regulation raise type reserve services.
With the coefficient represented by a(i,j) the following term is added to the formulation:
... + a(i,j) × ∑ ( i ∈ Type = "Regulation Raise" ) ( Power2X Reserves Provisioni ) ... {≤, ≥, =} bjwhere:
i indexes the Reserves provided by the Power2XBy default, this sum includes all Power2X Reserves of Type = "Regulation Raise". You can limit the set of Reserves included in this sum by adding Power2X Reserves memberships with no associated property definitions. This is a special case of using 'null' memberships to filter the terms included in another constraint property.
See also:
- Power2X Constraints Reserve Provision Coefficient
- Power2X Constraints Spinning Reserve Coefficient
- Power2X Constraints Raise Reserve Provision Coefficient
- Power2X Constraints Lower Reserve Provision Coefficient
- Power2X Constraints Regulation Lower Reserve Provision Coefficient
- Power2X Constraints Replacement Reserve Provision Coefficient