Production Fuel Use Function Precision

Units: -
Default Value: 0
Validation Rule: ≥0
Description: Precision for calculation of linear approximation to fuel function.
Detail:

Production Fuel Use Function Precision sets a tolerance when fitting a step function to a generator’s marginal heat rate function. Steps (tranches) are added until the tolerance is met or the Max Heat Rate Tranches is hit.

Refer to the article Heat Rate Modelling for more details.