RSI Non Utility Contract Volume

Units: MW
Mode: Output Only
Multi-band: False
Default Value:
Validation Rule:
Key Property: No
Description: Non Utility Contract Volume
Detail:

RSI Non Utility Contract Volume is defined as:

if there are generation contracts defined then:

∑ ( Financial Contract Quantity )

otherwise:

∑ ( ( 1.0 - Strategic ) )

The sum is taken over all companies.