Region Capacity Reserves
Units: | MW |
Mode: | Output Only |
Multi-band: | False |
Default Value: | |
Validation Rule: | |
Key Property: | No |
Description: | Capacity reserves (net of Peak Load) |
Detail: |
Region Capacity Reserves is the megawatt capacity reserve margin. The definition of this property depends on the simulation phase.
- PASA
-
Capacity Reserves reported by PASA is the capacity margin after allowances for maintenance i.e it is defined as:
Capacity Reserves = ∑ ( Generators Rated Capacity ) - Peak Load - Discrete Maintenance - Distributed Maintenance - Expected Forced Outage - Net Capacity Interchangewhere:
Expected Forced Outage = ∑ ( Generators Rated Capacity* Generator Forced Outage Rate ) - LT Plan
-
Capacity Reserves reported by LT Plan is defined as:
Capacity Reserves = Firm Generation Capacity + Curtailable Load - Planning Peak Load - Net Capacity Interchange
- MT Schedule and ST Schedule
-
Capacity Reserves reported by MT Schedule and ST Schedule is defined as:
Capacity Reserves = Firm Generation Capacity + Curtailable Load - Peak Load - Net Capacity Interchange