Region Unserved Energy
Units: | MW |
Mode: | Output Only |
Multi-band: | False |
Default Value: | |
Validation Rule: | |
Key Property: | No |
Description: | Unserved energy (USE) |
Detail: |
Region Unserved Energy is Load that could not be met due to a shortage in Generation and/or transmission capacity and is defined as:
\begin{equation} \text{Unserved Energy} = \sum_{ i \in \href{Node.Region.html}{\text{Nodes}}} \href{Node.UnservedEnergy.html}{\text{Unserved Energy}}_{i} \end{equation}See also: