Reserve Batteries Min Regulation Provision
Units: | MW |
Mode: | Input Only |
Multi-band: | False |
Default Value: | 0 |
Validation Rule: | ≥0 |
Key Property: | No |
Description: | Minimum regulation reserve provision when units are in the regulation range |
Detail: |
Reserve Batteries
Min Regulation Provision is Minimum regulation reserve provision when
units are in the regulation range. The following constraint is added
to the mathematical programming problem:
Regulation Reserve Provision ≥ Units Generating × Min Regulation
Provision
if-and-only-if
Regulation Point ≤ Battery Generation ≤ Regulation Point + Regulation
Range