Stochastic Outage Scope
Units: | - |
Default Value: | 0 |
Validation Rule: | In (0,1,2,3) |
Description: | Scope of preschedule outage pattern generator. |
Detail: |
Stochastic Outage Scope switches automatically generated random (forced) outages and distributed maintenance on/off. It can take the following values:
- All (value = 0)
- All randomly generated outages are included.
- Forced Only (value = 1)
- Forced outages are included, distributed maintenance excluded.
- Maintenance Only (value = 2)
- Maintenance outages are included, forced outages excluded.
- Planned Only (value = 3)
- Only planned outages are included.
Note:
- The algorithm used to produce these outages is controlled by the Monte Carlo Method option.
- Discrete Maintenance is always included in the simulation. If you want to turn off discrete maintenance, scenario the Units Out data out of the Model.