VariableLines Flowing Back Coefficient
Units: | - |
Mode: | Input Only |
Multi-band: | False |
Default Value: | 0 |
Validation Rule: | Any Value |
Key Property: | No |
Description: | Boolean value (1 if the line is flowing in the counter-reference direction, 0 otherwise) |
Detail: |
Variable Lines Flowing Back Coefficient is the coefficient on the logical condition that the line flow is in the counter-reference direction, in the dynamic equation that decides when the condition is active.
Example:
Variable | Property | Value | Units |
---|---|---|---|
V-SA IMPORTING | Profile | 1 | - |
V-SA IMPORTING | Condition | = |
Variable | Lines | Property | Value | Units |
---|---|---|---|---|
V-SA IMPORTING | V-SA | Flowing Back | 1 | - |
Inside the simulation Flowing Back will take the value 1 (true) when the line is flowing in the counter-reference direction and 0 (false) at other times. Thus in this example the condition is active equation is:
V-SA IMPORTING Is Active if:1 x VSA Flowing Back = 1 where VSA Flowing Back is either 0 or 1.See also: