Zone Capacity Reserves

Units: MW
Mode: Output Only
Multi-band: False
Default Value:
Validation Rule:
Key Property: No
Description: Capacity reserves (net of Peak Load)
Detail:

Zone Capacity Reserves is the megawatt capacity reserve margin. The definition of this property depends on the simulation phase.

PASA

Capacity Reserves reported by PASA is the capacity margin after allowances for maintenance i.e it is defined as:

Capacity Reserves = Rated Capacity - Peak Load - Discrete Maintenance - Distributed Maintenance
LT Plan

Capacity Reserves reported by LT Plan is defined as:

Capacity Reserves = Firm Generation Capacity + Curtailable Load - Planning Peak Load - Net Capacity Interchange
MT Schedule and ST Schedule

Capacity Reserves reported by MT Schedule and ST Schedule is defined as:

Capacity Reserves = Firm Generation Capacity + Curtailable Load - Peak Load - Net Capacity Interchange

See also: