Units: | MW |
Mode: | Input Only |
Multi-band: | False |
Default Value: | 0 |
Validation Rule: | Any Value |
Key Property: | No |
Description: | Coefficient of ramp |
Battery Constraints Ramp Coefficient specifies the coefficient applied to the battery's ramping behavior on the left-hand side of the constraints during the discharging phase. It defines how quickly the battery can change its power output when generating electricity. This property operates similarly to the Generator Constraints Ramp Coefficient and is used to regulate the ramping dynamics of the battery in line with operational constraints.
NOTE: This coefficient applies only during the discharging phase (i.e., when the battery is generating power) and does not impact the charging phase.