Units: | MW |
Mode: | Input Only |
Multi-band: | False |
Default Value: | 0 |
Validation Rule: | Any Value |
Key Property: | No |
Description: | Coefficient of ramp up |
Battery Constraints Ramp Up Coefficient specifies the coefficient applied to the left-hand side of the constraints that determines how quickly the battery can increase its power output during the discharging phase. It regulates the rate at which the battery ramps up its generation to respond to system demands or grid conditions.
NOTE: This coefficient is applicable only when the battery is discharging and ensures a controlled increase in power output to maintain system reliability and efficiency.