Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Is Enabled | Yes/No | False | 0 | In (0,-1) | True | If the contingency is enabled |
Monitoring Threshold | % | False | 100 | Between 0 And 100 | False | Monitor only this percentage of most affected Line/Transformer/Interface flows. |
Screening Elements | - | False | 0 | In (0,1,2) | False | Determines which lines/transformers would be screened for post-contingency flow under this contingency |
x | - | True | 0 | False | Value to pass-through to solution | |
y | - | True | 0 | False | Value to pass-through to solution | |
z | - | True | 0 | False | Value to pass-through to solution |
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Max Flow Limit | MW | False | 0 | False | Post-contingency flow limit in the reference direction | |
Min Flow Limit | MW | False | 0 | False | Post-contingency flow limit in the counter-reference direction |
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Flow Limit | MW | False | 0 | False | Post-contingency flow limit |
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Max Flow Limit | MW | False | 0 | False | Post-contingency flow limit in the reference direction | |
Min Flow Limit | MW | False | 0 | False | Post-contingency flow limit in the counter-reference direction |
Name | Summary Name | Property Group | Phases | Multi-band | Description |
---|---|---|---|---|---|
Hours Binding - h | Hours Binding - h | Production | LT Plan, MT Schedule, ST Schedule | False | Number of hours that any monitored limit under the Contingency is binding. |
Shadow Price - $/MW | Shadow Price - $/MW | Production | LT Plan, MT Schedule, ST Schedule | False | Contingency shadow price |
x | x | Pass-through | LT Plan, MT Schedule, ST Schedule | True | Value to pass-through to solution |
y | y | Pass-through | LT Plan, MT Schedule, ST Schedule | True | Value to pass-through to solution |
z | z | Pass-through | LT Plan, MT Schedule, ST Schedule | True | Value to pass-through to solution |
Name | Summary Name | Property Group | Phases | Multi-band | Description |
---|---|---|---|---|---|
Post-Contingency Flow - MW | Post-Contingency Flow - GWh | - | LT Plan, MT Schedule, ST Schedule | False | Post-Contingent Flows |
Shadow Price - $/MWh | Shadow Price - $/MWh | - | LT Plan, MT Schedule, ST Schedule | False | Shadow price for contingency constraint |
Name | Summary Name | Property Group | Phases | Multi-band | Description |
---|---|---|---|---|---|
Post-Contingency Flow - MW | Post-Contingency Flow - GWh | - | LT Plan, MT Schedule, ST Schedule | False | Post-Contingent Flows |
Shadow Price - $/MWh | Shadow Price - $/MWh | - | LT Plan, MT Schedule, ST Schedule | False | Shadow price for contingency constraint |
Name | Summary Name | Property Group | Phases | Multi-band | Description |
---|---|---|---|---|---|
Post-Contingency Flow - MW | Post-Contingency Flow - GWh | - | LT Plan, MT Schedule, ST Schedule | False | Post-Contingent Flows |
Shadow Price - $/MWh | Shadow Price - $/MWh | - | LT Plan, MT Schedule, ST Schedule | False | Shadow price for contingency constraint |