Name | Units | Default Value | Validation Rule | Description |
---|---|---|---|---|
Energy Density | - | 0 | Energy per unit of the gas | |
Unit | - | 0 | Unit the gas is measured in |
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Annual Expansion Max Reduction | 1000·~ (Metric), ~ (U.S. Imperial) | True | 0 | ≥0 | False | Annual Expansion max reduction offtake associated with the gas dsm program |
Capital Cost | $000 | False | 0 | False | Capital cost of gas dsm program | |
Customer Count | - | False | 0 | False | Number of customers (that have demand values) | |
Economic Life | yr | False | 30 | ≥0 | False | Economic life of the Gas dsm program (period over which fixed costs are recovered). |
Eligibility Date | - | False | 36526 | ≥0 | False | Start date of Gas dsm program planning. |
Expansion Max Reduction | 1000·~ (Metric), ~ (U.S. Imperial) | True | 0 | ≥0 | False | Expansion max reduction offtake associated with the gas dsm program |
Expansion Optimality | - | False | 0 | In (0,2) | False | Expansion planning integerization scheme. |
Expansion Program | Yes/No | False | 0 | In (0,1) | False | Indicates if Gas DSM program is eligible |
FO&M Charge | $000 | False | 0 | False | Annual fixed operation and maintenance charge | |
Integerization Horizon | yr | False | -1 | ≥-1 | False | Number of years over which the expansion decisions are integerized |
Is Available | Yes/No | False | 1 | In (0,1) | False | Indicates if Gas DSM Program is available |
Program Length | yr | False | 1E+30 | ≥0 | False | Technical Life of Gas dsm program |
Reduction Amount | 1000·~ (Metric), ~ (U.S. Imperial) | False | 0 | ≥0 | False | Demand reduction caused by gas dsm program |
Reduction Type | - | False | 0 | In (0,2) | False | Function structure for gas dsm program type inputs |
Usage Factor Base | - | False | 0 | False | Scalar demand value regardless of heat | |
Usage Factor Heat | - | True | 0 | False | Scalar heat value regardless of demand | |
Usage Factor Heat Point | - | True | 0 | False | Scalar temperature or HDD levels for piecewise linear function | |
Variable Cost | $/~ | True | 0 | False | Variable cost of gas dsm program | |
WACC | % | False | 10 | ≥0 | False | Weighted average cost of capital |
Weather Data Factor | - | True | 0 | False | Weather data factor for gas demand function | |
Weather Data Variable | - | True | 0 | False | Weather data variable for gas demand function | |
x | - | True | 0 | False | Value to pass-through to solution | |
y | - | True | 0 | False | Value to pass-through to solution | |
z | - | True | 0 | False | Value to pass-through to solution |
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Share | % | False | 100 | Between 0 And 100 | False | DSM Program's share of the gas demand |
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Units Built Coefficient | - | False | 0 | False | Coefficient of number of units built | |
Units Retired Coefficient | - | False | 0 | False | Coefficient of number of units retired |
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Units Built Coefficient | - | False | 0 | False | Coefficient of number of units built | |
Units Retired Coefficient | - | False | 0 | False | Coefficient of number of units retired |
Name | Summary Name | Property Group | Phases | Multi-band | Description |
---|---|---|---|---|---|
Capital Cost - $000 | Capital Cost - $000 | Expansion | LT Plan | False | Capital cost of the gas dsm program |
Fixed Costs - $ | Fixed Costs - $000 | Production | LT Plan, MT Schedule, ST Schedule | False | Total fixed costs |
FO&M Cost - $ | FO&M Cost - $000 | Production | LT Plan, MT Schedule, ST Schedule | False | Fixed operation and maintenance cost |
Reduction Amount - GJ (Metric), MMBtu (U.S. Imperial) | Reduction Amount - TJ (Metric), BBtu (U.S. Imperial) | Production | LT Plan, MT Schedule, ST Schedule | False | Demand reduction caused by gas dsm program |
Reduction Amount Built - TJ (Metric), BBtu (U.S. Imperial) | Reduction Amount Built - TJ (Metric), BBtu (U.S. Imperial) | Expansion | LT Plan | False | Amount of reduction caused by gas dsm program |
Variable Cost - $ | Variable Cost - $000 | Production | LT Plan, MT Schedule, ST Schedule | False | Variable cost of gas dsm program |
x | x | Pass-through | LT Plan, MT Schedule, ST Schedule | True | Value to pass-through to solution |
y | y | Pass-through | LT Plan, MT Schedule, ST Schedule | True | Value to pass-through to solution |
z | z | Pass-through | LT Plan, MT Schedule, ST Schedule | True | Value to pass-through to solution |