Name | Units | Default Value | Validation Rule | Description |
---|---|---|---|---|
Latitude | ° | 0 | Latitude | |
Longitude | ° | 0 | Longitude |
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Allow Dump Heat | Yes/No | False | 0 | In (0,-1) | False | Model Heat Node [Dump Heat] in the mathematical program. |
Allow Unserved Heat | Yes/No | False | 0 | In (0,-1) | False | Model Heat Node [Unserved Heat] in the mathematical program. |
Heat Demand | GJ (Metric), MMBtu (U.S. Imperial) | False | 0 | False | Heat demand at the node | |
Units | - | False | 1 | In (0,1) | True | Number of Heat Node units in service |
x | - | True | 0 | False | Value to pass-through to solution | |
y | - | True | 0 | False | Value to pass-through to solution | |
z | - | True | 0 | False | Value to pass-through to solution |
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Participation Factor | - | False | 1 | Between -1 And 1 | False | Proportion sent to the node |
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Consumption Coefficient | - | False | 0 | False | Heat consumption for each unit of consumption | |
Facility Node Type | - | False | 0 | In (0, 1, 2) | False | Specifies whether Node is an input or an output for the Facility |
Production Coefficient | - | False | 0 | False | Heat production for each unit of production | |
Units Coefficient | - | False | 0 | False | Heat consumption for each installed unit | |
Units Operating Coefficient | - | False | 0 | False | Heat consumption for each unit operating |
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Heat Flow Coefficient | GJ (Metric), MMBtu (U.S. Imperial) | False | 0 | False | Coefficient of heat flow through the heat node |
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Heat Flow Coefficient | GJ (Metric), MMBtu (U.S. Imperial) | False | 0 | False | Coefficient of heat flow through the heat node |
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Heat Flow Coefficient | GJ (Metric), MMBtu (U.S. Imperial) | False | 0 | False | Coefficient of heat flow through the heat node in condition |
Name | Summary Name | Property Group | Phases | Multi-band | Description |
---|---|---|---|---|---|
Facility Load - MW | Facility Load - GWh | Production | LT Plan, MT Schedule, ST Schedule | False | Load from connected Facilities |
Heat Demand - GJ (Metric), MMBtu (U.S. Imperial) | Heat Demand - TJ (Metric), BBtu (U.S. Imperial) | Production | LT Plan, MT Schedule, ST Schedule | False | Demand at the heat node |
Heat Injection - GJ (Metric), MMBtu (U.S. Imperial) | Heat Injection - TJ (Metric), BBtu (U.S. Imperial) | Production | LT Plan, MT Schedule, ST Schedule | False | Heat injected into heat node |
Heat Withdrawal - GJ (Metric), MMBtu (U.S. Imperial) | Heat Withdrawal - TJ (Metric), BBtu (U.S. Imperial) | Production | LT Plan, MT Schedule, ST Schedule | False | Heat withdrawn from heat node |
x | x | Pass-through | LT Plan, MT Schedule, ST Schedule | True | Value to pass-through to solution |
y | y | Pass-through | LT Plan, MT Schedule, ST Schedule | True | Value to pass-through to solution |
z | z | Pass-through | LT Plan, MT Schedule, ST Schedule | True | Value to pass-through to solution |
Name | Summary Name | Property Group | Phases | Multi-band | Description |
---|---|---|---|---|---|
Cost - $ | Cost - $000 | - | LT Plan, MT Schedule, ST Schedule | False | Cost of purchases from the market |
Net Cost - $ | Net Cost - $000 | - | LT Plan, MT Schedule, ST Schedule | False | Net of revenue and cost |
Net Purchases - GJ (Metric), MMBtu (U.S. Imperial) | Net Purchases - TJ (Metric), BBtu (U.S. Imperial) | - | LT Plan, MT Schedule, ST Schedule | False | Net purchases from the market |
Net Revenue - $ | Net Revenue - $000 | - | LT Plan, MT Schedule, ST Schedule | False | Net of cost and revenue |
Net Sales - GJ (Metric), MMBtu (U.S. Imperial) | Net Sales - TJ (Metric), BBtu (U.S. Imperial) | - | LT Plan, MT Schedule, ST Schedule | False | Net sales to the market |
Purchases - GJ (Metric), MMBtu (U.S. Imperial) | Purchases - TJ (Metric), BBtu (U.S. Imperial) | - | LT Plan, MT Schedule, ST Schedule | False | Purchases from the market |
Revenue - $ | Revenue - $000 | - | LT Plan, MT Schedule, ST Schedule | False | Revenue from sales to the market |