Name | Units | Default Value | Validation Rule | Description |
---|---|---|---|---|
Latitude | ° | 0 | Latitude | |
Longitude | ° | 0 | Longitude |
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Build Cost | $000 | True | 0 | False | Cost of building the water node | |
Economic Life | yr | False | 30 | ≥0 | False | Economic life of the water node (period over which fixed costs are recovered). |
Expansion Optimality | - | False | 2 | In (0,2) | False | Expansion planning integerization scheme. |
Flow Charge | $/m³ (Metric), $/gal. (U.S. Imperial) | False | 0 | False | Incremental cost of flowing water through the node | |
FO&M Charge | $000 | False | 0 | False | Annual fixed operation and maintenance charge | |
Integerization Horizon | yr | False | -1 | ≥-1 | False | Number of years over which the expansion decisions are integerized |
Lead Time | yr | False | 0 | ≥0 | False | Number of years after which the expansion project can begin |
Max Units Built | - | False | 0 | In (0,1) | False | Binary indicating if this is a build candidate |
Max Units Built in Year | - | False | 1 | In (0,1) | False | Binary indicating if build is allowed in this year |
Max Units Retired | - | False | 0 | In (0,1) | False | Maximum number of units automatically retired in aggregate over the planning horizon |
Max Units Retired in Year | - | False | 1 | In (0,1) | False | Maximum number of units automatically retired in any single year of the planning horizon |
Min Units Built | - | False | 0 | In (0,1) | False | Minimum number of units automatically constructed in aggregate over the planning horizon |
Min Units Built in Year | - | False | 0 | In (0,1) | False | Minimum number of units automatically constructed in any single year of the planning horizon |
Min Units Retired | - | False | 0 | In (0,1) | False | Minimum number of units automatically retired in aggregate over the planning horizon |
Min Units Retired in Year | - | False | 0 | In (0,1) | False | Minimum number of units automatically retired in any single year of the planning horizon |
Project Start Date | - | False | 36526 | ≥0 | False | Start date of water node project, for expansion planning. |
Retirement Cost | $000 | False | 0 | False | Cost of retiring the water node | |
Technical Life | yr | False | 1E+30 | ≥0 | False | Technical lifetime of the water node |
Units | - | False | 1 | In (0,1) | True | Flag if the Water Node is in service |
WACC | % | False | 10 | ≥0 | False | Weighted average cost of capital |
x | - | True | 0 | False | Value to pass-through to solution | |
y | - | True | 0 | False | Value to pass-through to solution | |
z | - | True | 0 | False | Value to pass-through to solution |
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Consumption Coefficient | - | False | 0 | False | Water consumption for each unit of consumption | |
Production Coefficient | - | False | 0 | False | Water production for each unit of production | |
Units Coefficient | - | False | 0 | False | Water consumption for each installed unit | |
Units Operating Coefficient | - | False | 0 | False | Water consumption for each unit operating |
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Flow Coefficient | m³ (Metric), gal. (U.S. Imperial) | False | 0 | False | Coefficient of water node flow | |
Units Built Coefficient | - | False | 0 | False | Coefficient of number of units built | |
Units Built in Year Coefficient | - | False | 0 | False | Coefficient of number of units built in the year | |
Units Retired Coefficient | - | False | 0 | False | Coefficient of number of units retired | |
Units Retired in Year Coefficient | - | False | 0 | False | Coefficient of number of units retired in the year |
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Flow Coefficient | m³ (Metric), gal. (U.S. Imperial) | False | 0 | False | Coefficient of water node flow | |
Units Built Coefficient | - | False | 0 | False | Coefficient of number of units built | |
Units Built in Year Coefficient | - | False | 0 | False | Coefficient of number of units built in the year | |
Units Retired Coefficient | - | False | 0 | False | Coefficient of number of units retired | |
Units Retired in Year Coefficient | - | False | 0 | False | Coefficient of number of units retired in the year |
Name | Summary Name | Property Group | Phases | Multi-band | Description |
---|---|---|---|---|---|
Build Cost - $000 | Build Cost - $000 | Expansion | LT Plan | False | Cost of building the water node |
Demand - m³/day (Metric), gal./day (U.S. Imperial) | Demand - m³ (Metric), gal. (U.S. Imperial) | Production | LT Plan, MT Schedule, ST Schedule | False | Demand at the water node |
End Volume - m³ (Metric), gal. (U.S. Imperial) | End Volume - m³ (Metric), gal. (U.S. Imperial) | Production | LT Plan, MT Schedule, ST Schedule | False | End volume in water storage |
Energy Consumption - MW | Energy Consumption - GWh | Production | LT Plan, MT Schedule, ST Schedule | False | Total energy consumed for pipeline utilization |
Excess - m³/day (Metric), gal./day (U.S. Imperial) | Excess - m³ (Metric), gal. (U.S. Imperial) | Production | LT Plan, MT Schedule, ST Schedule | False | Excess of water supply |
Excess Cost - $ | Excess Cost - $000 | Production | LT Plan, MT Schedule, ST Schedule | False | Cost of water excesses |
Excess Hours - h | Excess Hours - h | Production | LT Plan, MT Schedule, ST Schedule | False | Number of hours of excess supply of water at the node |
Exports - m³/day (Metric), gal./day (U.S. Imperial) | Exports - m³ (Metric), gal. (U.S. Imperial) | Production | LT Plan, MT Schedule, ST Schedule | False | Exports on water pipelines |
Facility Consumption - m³ (Metric), gal. (U.S. Imperial) | Facility Consumption - m³ (Metric), gal. (U.S. Imperial) | Production | LT Plan, MT Schedule, ST Schedule | False | Water consumed by connected Facilities |
Fixed Costs - $ | Fixed Costs - $000 | Production | LT Plan, MT Schedule, ST Schedule | False | Total fixed costs including amortized build costs |
Flow - m³/day (Metric), gal./day (U.S. Imperial) | Flow - m³ (Metric), gal. (U.S. Imperial) | Production | LT Plan, MT Schedule, ST Schedule | False | Flow of water through the node |
Flow Cost - $ | Flow Cost - $000 | Production | LT Plan, MT Schedule, ST Schedule | False | Cost of flowing water through the node |
FO&M Cost - $ | FO&M Cost - $000 | Production | LT Plan, MT Schedule, ST Schedule | False | Fixed operation and maintenance cost |
Imports - m³/day (Metric), gal./day (U.S. Imperial) | Imports - m³ (Metric), gal. (U.S. Imperial) | Production | LT Plan, MT Schedule, ST Schedule | False | Imports on water pipelines |
Initial Volume - m³ (Metric), gal. (U.S. Imperial) | Initial Volume - m³ (Metric), gal. (U.S. Imperial) | Production | LT Plan, MT Schedule, ST Schedule | False | Initial volume in water storage |
Net Interchange - m³/day (Metric), gal./day (U.S. Imperial) | Net Interchange - m³ (Metric), gal. (U.S. Imperial) | Production | LT Plan, MT Schedule, ST Schedule | False | Net exports on water pipelines |
Production - m³/day (Metric), gal./day (U.S. Imperial) | Production - m³ (Metric), gal. (U.S. Imperial) | Production | LT Plan, MT Schedule, ST Schedule | False | Total quantity of water supplied by Supplying Water Plants |
Retirement Cost - $000 | Retirement Cost - $000 | Expansion | LT Plan | False | Cost of retiring the water node |
Shadow Price - $/m³ (Metric), $/gal. (U.S. Imperial) | Shadow Price - $/m³ (Metric), $/gal. (U.S. Imperial) | Production | LT Plan, MT Schedule, ST Schedule | False | Shadow price of water at the water node |
Shortage - m³/day (Metric), gal./day (U.S. Imperial) | Shortage - m³ (Metric), gal. (U.S. Imperial) | Production | LT Plan, MT Schedule, ST Schedule | False | Shortage of water supply |
Shortage Cost - $ | Shortage Cost - $000 | Production | LT Plan, MT Schedule, ST Schedule | False | Cost of water supply shortages |
Shortage Hours - h | Shortage Hours - h | Production | LT Plan, MT Schedule, ST Schedule | False | Number of hours of shortage in supply of water at the node |
Units | Units | Production | LT Plan | False | Flag if the Water Node is in service |
Units Built | Units Built | Expansion | LT Plan | False | Flag if the water node is built in this year |
Units Retired | Units Retired | Expansion | LT Plan | False | Number of water node units retired |
x | x | Pass-through | LT Plan, MT Schedule, ST Schedule | True | Value to pass-through to solution |
y | y | Pass-through | LT Plan, MT Schedule, ST Schedule | True | Value to pass-through to solution |
z | z | Pass-through | LT Plan, MT Schedule, ST Schedule | True | Value to pass-through to solution |