Region Internal VoLL Level

Units:MWh
Mode:Input Only
Multi-band:True
Default Value:0
Validation Rule:Any Value
Key Property:No
Description:Level of unserved energy VoLL applies to

This parameter can be paired with Internal VoLL to define the notional cost of unserved energy as a function of the magnitude of the load lost.

Note:

Example: In the example below, we have two bands of unserved energy along with their corresponding values. A cost of $1000/MWh is used for unserved energy up to 10,000 MWh and $2000 /MWh up to 20,000 MWh. Beyond that level, additional unserved energy is priced at Transmission Internal VoL.

Band Internal VoLL ($/MWh) Internal VoLL Level (MWh)
1 1000 10000
2 2000 10000