Region Price Cap

Units:$/MWh
Mode:Input Only
Multi-band:False
Default Value:1E+30
Validation Rule:Any Value
Key Property:No
Description:Cap on generator offer prices

Region Price Cap places an upper limit on any generator Offer Price. This limit is applied both to internally calculated offer prices as well as user-defined offer prices.

Example:

Region Property Value Units
AREA1 Price Cap 250 -
AREA1 Price Floor -150 -

In this example generator offer prices will be limited between -150 and 250.

Price Floor and Price Cap act only to limit generator offer prices. If other constraints or unserved energy or dump energy occur the clearing price, which is bounded between (the negative of) Price of Dump Energy and VoLL, can exceed those limits.

Note that if Price Cap is omitted the value of VoLL is used.