Zone Firm Capacity Groups Capacity Points

Units:MW
Mode:Input Only
Multi-band:True
Default Value:0
Validation Rule:Any Value
Key Property:No
Description:Capacity points used for approximating the firm capacity surface

Zone Firm Capacity Groups Capacity Points input is used for modeling multi-dimensional firm capacity curves in LT Plan. Each point is specified on a different band, and this input represents a total capacity value for this Firm Capacity Group. It corresponds to the same band of the Capacity Points for other Firm Capacity Groups as well as the Firm Capacity Values specified for the Zone. It is recommended to include points from all parts of the surface and that the number of points be at least as large as twice the product of all the Max Tranches inputs for each Firm Capacity Group connected to the Zone.