Battery Initial SoC

Units:%
Mode:Input Only
Multi-band:False
Default Value:0
Validation Rule:≥0
Key Property:No
Description:Initial State of Charge

Battery Initial SoC is the initial State of Charge of a BESS unit, at the start of the first period of the Horizon.

Example:

Storage Property Value Units
Battery1 Max Power 25 MW
Battery1 Capacity 2 MWh
Battery1 Max SoC 90 %
Battery1 Min SoC 10 %
Battery1 Initial SoC 10 %

The example shows a typical set up for a BESS unit.