Battery Max SoC

Units:%
Mode:Input Only
Multi-band:False
Default Value:100
Validation Rule:≥0
Key Property:No
Description:Allowable maximum State of Charge

Battery Max SoC is the allowable maximum State of Charge. This is expressed as a percentage of the commissioned Capacity (i.e. before any Capacity Degradation).

Example:

Battery Property Value Units
Battery1 Capacity 25 GWh
Battery1 Max SoC 90 %

The maximum state of charge that this BESS could obtain is 90% of 25 GWh, which is 22.5 GWh.