Units: | - |
Mode: | Input/Output |
Multi-band: | True |
Default Value: | 0 |
Validation Rule: | ≥0 |
Key Property: | No |
Description: | Number of units out of service due to maintenance |
Facility Units Out defines 'discrete' (or planned) maintenance events. The property can be used with the Date From and Date To fields to set the exact period of outage. Units Out can also be defined with a Variable or Data File object. Units Out is a multi-band property. Each band defines an outage of the severity defined in that band.
Property | Value | Units | Band | Date From | Date To |
Units Out | 1 | - | 1 | 1/02/2006 | 1/05/2006 |
Units Out | 1 | - | 1 | 4/05/2006 | 4/09/2006 |
Units Out | 1 | - | 2 | 9/26/2006 | 9/26/2006 |
Outage Rating | 0 | - | 1 | ||
Outage Rating | 200 | - | 2 |
For the example in Table 1 there are two types of outage
(identified by bands one and two respectively). The band one
outages are total outages (Outage
Rating = 0).
Facilities are modeled as single unit (Units = 1) or multiple unit (Units > 1). When modelling forced (random) outages and maintenance outages, units at multi-unit stations are tracked individually in the simulation so it possible to have both types of outages in the same period on different units.
The total Discrete Maintenance (as defined by Units Out) is summed up and subtracted from the Distributed Maintenance requirement (defined by Maintenance Rate).
See also: