Units: | ~ |
Mode: | Output Only |
Multi-band: | False |
Default Value: | |
Validation Rule: | |
Key Property: | No |
Description: | Capacity out on maintenance |
Facility Maintenance is the production capacity on maintenance outage. This can be defined using a Variable or passed as an input from an Interleaved simulation to coordinate maintenance outages between models.
The definition of the Maintenance as an output varies by simulation phase:
Maintenance reports the derating applied to capacity to account for Maintenance Rate:
Maintenance = ∑ ( b ) ( Maintenance Rateb × (Max Operating Level - Outage Ratingb)
where:
b indexes the bands
of Maintenance Rate
Maintenance is the sum of the user-defined maintenance and the 'idealized' maintenance profile:
Maintenance = Discrete Maintenance + Distributed Maintenance
Maintenance reports the capacity on maintenance from the realized maintenance events (combination of user-defined and those generated by PASA). Thus for any given event:
Maintenance =∑ ( b ) (Max Operating Level - Outage Ratingb) × Units Outb
Note that if MT Schedule Chronology = "Partial" then multiple discrete events may combine together in any given period as a function of the slicing of the duration curves and thus this profile may then resemble a sculpted derating rather than discrete events.