Units: | ~ |
Mode: | Input/Output |
Multi-band: | False |
Default Value: | 0 |
Validation Rule: | Any Value |
Key Property: | No |
Description: | Minimum fuel offtake per interval |
As input Fuel Min Offtake is the minimum amount of fuel that must be used in any interval of the simulation. For multi-period limits see the properties Min Offtake HOUR, Min Offtake DAY, Min Offtake WEEK, Min Offtake MONTH, Min Offtake YEAR.
For this value to be treated as a hard constraint, the Min Offtake Penalty needs to be set to -1. Otherwise, this value is treated as a soft constraint.
As output Fuel Min Offtake is the minimum Offtake in the period.
See also: