Transmission Allow Dump Energy

Units:Yes/No
Default Value:True (-1)
Validation Rule:False (0) or True (-1)
Description:Model Dump Energy in OPF

Transmission Allow Dump Energy is the master on/off switch for modelling of dump energy (excess generation). By default dump energy is allowed and will be invoked whenever a locational price for energy falls below the price of dump energy. Turning off this option will reduce the size of the simulation problem and improve performance, but will result in an infeasibility if constraints in the model require that energy be dumped. Such constraints include must-run constraints and other constraints that force generation in periods when the load is not sufficient to take up the generation.

Please note: