DecisionVariable: Decision Variable Balancing Region To
Required Members: | 0 |
Maximum Members: | 1 |
Description: | Set of Balancing Region To objects involved in the Decision Variable |
Detail: |
Decision Variable Balancing Region To is designed to work along with the Decision Variable Balancing Region From membership to expose the Balancing Area Interchange between a single pair on regional interchange. Balancing Region To defines the "to" Region object of the pair.
When both Balancing Region To and Balancing Region From memberships are populated, Plexos will automatically add definition constraints that equate the economic interchange to the decision variable. Custom Constraints can then be placed on Decision Variable. This allows modeling market constraints, such as the MISO's Regional Directional Transfer constraint.
Example -
In the following setup, Decision Variable DV1 will be equal to Balancing Area Interchange from Region R1 to Region R2. Any custom constraint placed on DV1 will automatically apply to the Balancing Area Interchange as well.
See also: